Cells+Tissuebank Austria

Magnesitstraße 1, 3500 Krems an der Donau
Phone +43 (0) 2732 76954 - 0 | E-Mail office@ctba.at

EN / DE
Safety and Quality
Our transplants are manufactured to the highest quality standards.
ALLOGENEIC BONE TRANSPLANTS
Tailored to individual requirements and a variety of indications.
DONATE TISSUE!
Health and mobility. Many bone diseases can nowadays be cured with bone allografts. With your donor you can make a difference. 

SYMBOL GLOSSARY DEFINITIONS

SYMBOLS NOT FROM STANDARDS

SYMBOLGROUP SYMBOL TITLE SYMBOL  EXPLANATORY TEXT
Cancellous Granules Cancellous Granules - Dental
< 2 mm, small (0.25-1 mm), large (1-2 mm)
    Cancellous Granules
2-5 mm, 2-8 mm, 5-8 mm, 5-10 mm, >8 mm
Cancellous
Granules + HyA
Cancellous Granules + HyA - Dental
< 0,25 mm + Hyaluronic acid,
0,25-1 mm + Hyaluronic acid,
1-2 mm + Hyaluronic acid
Cancellous Granules, sawn Cancellous Granules, sawn
<10 mm
Applicator Cancellous Granules Applicator
7 cc, 15 cc, 30 cc
Cortico-Cancellous Granules

Cortico-Cancellous Granules - Dental
< 2 mm, small (0.25-1 mm), large (1-2 mm)

Cortico-Cancellous Granules + HyA

Cortico-Cancellous Granules + HyA - Dental
< 0,25 mm + Hyaluronic acid,
0,25-1 mm + Hyaluronic acid,
1-2 mm + Hyaluronic acid

Cortical Granules Cortical Granules - Dental
< 2 mm, small (0.25-1 mm), large (1-2 mm)
    Cortico-Cancellous Granules X 
< 2 mm, small (0.25-1 mm), large (1-2 mm), with a higher amount of cortical bone
    Cortico-Cancellous Granules
2-8 mm
Cortical Granules + HyA Cortical Granules Plus + HyA - Dental
< 0,25 mm + Hyaluronic acid,
0,25-1 mm + Hyaluronic acid,
1-2 mm + Hyaluronic acid
Cancellous Cubes Cancellous Cubes
5x5x5 mm - 10 cc, 20 cc
Cancellous Blocks

Cancellous Block
10x10x10 mm, 10x10x20mm, 10x20x30 mm
10x30x30 mm, 12x30x30 mm
10x30x40 mm, 10x30x50 mm
15x15x30 mm

Femural Head Femural Head
Femural Head, halved

Femural Head, halved
< 3 cm in diameter
< 4.5 cm in diameter
> 4.5 cm in diameter

Femural Head, bisected Femural Head, bisected
S = short = without column
L = long = with column
Cancellous Wedge

Cancellous Wedge
7° Angle - small and large
10° Angle - small and large
13° Angle - small and large
16° Angle - small and large 

Cortico-Cancellous Wedge Cortico-Cancellous
15° Angle 
Cancellous Cylinders

Cancellous Cylinders
Diameter 10 mm - Length 20 mm
Diameter 10 mm - Length 30 mm
Diameter 12 mm - Length 20 mm
Diameter 12 mm - Length 30 mm
Diameter 14 mm - Length 20 mm
Diameter 14 mm - Length 30 mm
Diameter 20 mm - Length 15 mm

Bonerings

Bonering 3.3
Inner diameter 3.3 mm - Outer diameter 6 mm
Inner diameter 3.3 mm - Outer diameter 7 mm

Bonering 4.1
Inner diameter 4.1 mm - Outer diameter 7 mm

Cancellous Ring 7.7

Cancellous Ring 7.7 - Inner diameter 7.7 mm
Outer diameter 26 mm - Height 10 mm
Outer diameter 26 mm - Height 20 mm
Outer diameter 32 mm - Height 10 mm
Outer diameter 32 mm - Height 20 mm

Cancellous Ring 1.5 Cancellous Ring 1.5 - Inner diameter 1.5 mm
Outer diameter 26 mm - Height 10 mm
Outer diameter 26 mm - Height 20 mm
Outer diameter 32 mm - Height 10 mm
Outer diameter 32 mm - Height 20 mm
Unicortical Block

Unicortical Block
10x10x10 mm - 10 mm length at the cortical portion
10x10x20 mm - 20 mm length at the cortical portion
10x10x30 mm - 30 mm length at the cortical portion

Tricortical Block Tricortical Block
10x10 mm, 20x20 mm, 20x30 mm, 20x10 mm,
30x20 mm, 40x20 mm
Cortical Struts

Cortical Struts
25 mm length x 10 mm width x 1 mm thickness
25 mm length x 10 mm width x 0.7 mm thickness

Diaphysis, halved Diaphysis, halved
Lenght: 100 mm, 150 mm, 200 mm
 
Fibula Ring

Fibula Ring
Length: 5 mm, 7 mm, 10 mm, 35 mm, 75 mm, 100 mm

       
J-Chip   J-Chip
Bonebuilder   Bonebuilder - Individual Boneblock

SYMBOLS FROM STANDARDS

SYMBOL STANDARD REFERENCE STANDARD TITLE SYMBOL TITLE EXPLANATORY TEXT
EN 980, Clause 5.12 Symbols for use in the labelling of medical devices. Manufacturer Indicates the medical device manufacturer.
ISO 15223-1, Clause 5.1.1 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-3082 Graphical symbols for use on equipment.
EN 980, Clause 5.6 Symbols for use in the labelling of medical devices. Date of manufacture Indicates the date when the medical device was manufactured.
ISO 15223-1, Clause 5.1.3 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-2497 Graphical symbols for use on equipment.
EN 980, Clause 5.10 Symbols for use in the labelling of medical devices. Catalogue or model number Indicates the manufacturer's catalogue number so that the medical device can be identified.
ISO 15223-1, Clause 5.1.6 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000- 2493 Graphical symbols for use on equipment.
EN 980, Clause 5.5 Symbols for use in the labelling of medical devices. Serial number Indicates the manufacturer's serial number so that a specific medical device can be identified.
ISO 15223-1, Clause 5.1.7 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-2498 Graphical symbols for use on equipment.
EN 980, Clause 5.4 Symbols for use in the labelling of medical devices. Batch code Indicates the manufacturer's batch code so that the batch or lot can be identified.
ISO 15223-1, Clause 5.1.5 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-2492 Graphical symbols for use on equipment.
EN 980, Clause 5.3 Symbols for use in the labelling of medical devices. Use by Indicates the date after which the medical device is not to be used.
ISO 15223-1, Clause 5.1.4 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-2607 Graphical symbols for use on equipment.
EN 980, Clause 5.18 Symbols for use in the labelling of medical devices. Consult instructions for use Indicates the need for the user to consult the instructions for use.
ISO 15223-1, Clause 5.4.3 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
IEC 60601-1, Table D.1, Symbol 11 Medical electrical equipment — Part 1: General requirements for basic safety and essential performance.
ISO 7000-1641 Graphical symbols for use on equipment.
EN 980, Clause 5.11 Symbols for use in the labelling of medical devices. Caution: Read all warnings and precautions in instructions for use Indicates the need for the user to consult the instructions for use for important cautionary information such as warnings and precautions that cannot, for a variety of reasons, be presented on the medical device itself.
ISO 15223-1, Clause 5.4.4 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
IEC 60601-1, Table D.1, Symbol 10 Medical electrical equipment — Part 1: General requirements for basic safety and essential performance.
ISO 7000-0434 Graphical symbols for use on equipment.
EN 980, Clause 5.17.3 Symbols for use in the labelling of medical devices. Storage temperature range Indicates the temperature limits to which the medical device can be safely exposed.
ISO 15223-1, Clause 5.3.7 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-0632 Graphical symbols for use on equipment
EN 980, Clause 5.21 Symbols for use in the labelling of medical devices. Keep dry Indicates a medical device that needs to be protected from moisture.
ISO 15223-1, Clause 5.3.4 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-0626 Graphical symbols for use on equipment.
EN 980, Clause 5.2 Symbols for use in the labelling of medical devices. Do not reuse Indicates a medical device that is intended for one use, or for use on a single patient during a single procedure.
ISO 15223-1, Clause 5.4.2 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-1051 Graphical symbols for use on equipment.
ISO 15223-1, Clause 5.2.8 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied. Do not use if package is damaged Indicates a medical device that should not be used if the package has been damaged or opened.
ISO 7000-2606 Graphical symbols for use on equipment.
EN 980, Clause 5.8.3 Symbols for use in the labelling of medical devices. Do not resterilize Indicates a medical device that is not to be resterilized.
ISO 15223-1, Clause 5.2.6 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-2608 Graphical symbols for use on equipment.
EN 980, Clause 5.8.3 Symbols for use in the labelling of medical devices. Sterilized using irradiation Indicates a medical device that has been sterilized using irradiation.
ISO 15223-1, Clause 5.2.4 Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied.
ISO 7000-2502 Graphical symbols for use on equipment.